HELP - Filter draining during the night • Pumping Station ...

I am troubleshooting a problem that ocurred after I replaced the filter, heater and had to replumb. I have solar. When the solar 3-way valve turns of for the night, it looks like in addition to the solar panels draining as they should, my filter is draining back into the pool overnight. In working with the Autopilot people, they think that with my current plumbing (see the second picture here If you look at the second picture, the output of the filter goes to the check valve and from there goes to the 3-way valve. When the solar 3-way valve closes at night, the panels drain (as they should), but because of the 3-way, allowing draining the panels, the water from the check valve empties, no longer offering resistance to stop the water from the filter to drain. They are suggesting that the output of the check valve to the 3-way solar valve should go up so that the 3-way solar valve is much higher than the check valve leaving the check valve with water in it to keep the flapper close through water pressure instead of allowing slow air leaks. Right now the multiport valve (filter) is level with the checkvalve and the 3-way valve, and with the solar side closed there is nothing to stop the filter from draining through the return. I can watch the check valve emptying. The path goes from the open side of the 3-way to the Mastertemp heater and out to the returns. Does this make sense? Thanks. It is a 3-way Jandy. According to Pentair and Pool Pilot, even with the spring, if the check valve has no water to exert some additional pressure, it is not totally airtight and air will get in. Water pressure helps keeping it shut (according to them). Their suggestion is to raise the 3-way valve connected to the output of the check valve about a foot. That would keep the water level in the filter at the same level of the Jandy 3-way valve (two colums of water equalize). That is their reazoning as to why the filter is draining out to the 3-way valve level. Does it make sense? Do I need to worry about heights of valves, etc? Actually, if you look at the picture, you will see that the plumbing from the filter output goes to the check valve, from the check valve to the 3-way. When the 3-way is in the non-solar position, the filter output has unrestricted flow path to the pool return, so what Pentair is saying is that the filter water level will find its level which will be the hight of the filter multiport valve (same hight of the check valve and 3-way).


Spa Jet Air Control Valve Retrofit - Bookshelf

Organic finishing

Organic finishing

In a spray gun, in combination; an air control unit comprising a handle having ... for opening said valve, a forward extension from said handle, an air jet ...

Aeroplane and commercial aviation news

Aeroplane and commercial aviation news

Industrie Aeronautiche e Meccaniche Rinaldo Piaggio SpA, Vlale Brigata Bisagno, ... as well as fuel control units (or Fiat G-91 and F-104 Starfighter jet ...

Chemical engineering

Chemical engineering

Inc Enviro-Seal Valve stem packing system; control fugitive emissions, Fisher Controls ... Aluminum Paste, Bangun Karunia Evactor Steam jet ejector. ...

International aerospace abstracts

International aerospace abstracts

Marco Porru (Fiat SpA , Divisione Aviazione, Ufficio Tecnico Studi Speciali, ... gas entry and discharge orifices, and a seat for the manual control valve. ...

The Complete Guide to Home Automation

The Complete Guide to Home Automation

Autospa Another choice in pool/spa remote control is the X- 10- compatible ... control up to two jet pumps, one or two air pumps, and spa and pool lights ...

Knowledge Base Directory


Spa Jet Retrofit
By rotating the adjustment handle, bathers can control the flow of water through the jet. ... parts that Hydro Air uses to perform a gunite retrofit installation: ...

Spa Jet Air Control Valve Retrofit
Spa Jet Air Control Valve Retrofit. Burnsville N C. Dtm And Dem. Austin Nv Blue Agate. How To Test Distributor Advance. Summer Girls Lfo. Beach Beauties Blog ...

Diverter Valve Retrofit, 1998 Hot Spring/Tiger River, 71799
(Ref. #2) This part is used to update the base of the Smart Jet on the 1998 Hot Spring & Tiger River spa models. This will allow the replacement valve levers and ...

Hydro Air Pool Spa
replacement parts for Hydro Air spa equipment ... 3 4In Nozzle Whirpool Jet Assy. Hydro Air. 3 4In Posi Seal Body. Hydro Air. 3 4In Posi Seal On Off Valve. Hydro Air. 3 4In Posi Seal ...

Thermostat, Control, Hot Spring, '94 Retrofit, 75087
This Electronic Control Thermostat replaces the mechanical thermostats in the 1994 Hot Spring Classic, Grandee, Highlife, Jetsetter, Prodigy and Sovereign spa models.
TOP